How to Test ASIN AQUA Salt Installation and Check for Air Bubbles

Learn how to test your ASIN AQUA Salt installation and fix air bubbles caused by pump air intake.

To ensure proper operation of your ASIN AQUA Salt system, perform a thorough test of all outputs after installation. In the “Test of Outputs” menu, gradually start all pumps and inspect every PE tube connection for tightness. Check the injecting valves for blockages and watch for air bubbles in the PE tubes. Air bubbles typically indicate that the pump is drawing air, which can be fixed by disconnecting the transparent plastic tube at the connection, cutting the end carefully at a 90° angle, and plugging it back. It is crucial to test the run and stop of all accessories connected to the system without dosing any chemicals or aids at this stage. Ensuring all connections are tight and liquid flows properly to the spraying tubes will prevent common installation issues and improve system reliability.